TITLE: Miswired CRT connector DATE: 8/6/91 PRODUCT: WY85 WY99GT WY50 THE ISSUE: The Monitor Power Supply board I just installed fails OVERVIEW: Improper marking (silk screen) for position of the "Blk" and "Brn" CRT connector wires on the Monitor Power Supply PCB. RESOLUTION: Desolder the connector wires from the PCBD. Change positions of the Brown, and Black wires...re-label the PCBD properly. =-=-=-=-=-=-=-=-=-=-=-=-= DISCLAIMER =-=-=-=-=-=-=-=-=-=-=-=-=-=-= This information is intended to inform WYSE personnel and WYSE customers of certain issues in a timely fashion. The information has not been extensively verified or tested. WYSE does not warrant the information to be correct, although reasonable effort has been taken to prevent gross inaccuracies. WYSE publishes formal technical communiques in the form of Product Bulletins and warrants the data in Product Bulletins to be accurate at the time of the release.